SUMMARY: model 114 array controller upgrade
2007-12-24 19:14:00
I was getting the following errors:
>ID[SUNWssa.soc.link.5010] soc2: port 0: Fibre Channel is OFFLINE
>ID[SUNWssa.soc.link.6010] soc2: port 0: Fibre Channel is ONLINE
>WARNING: /sbus at 1f,0/SUNW,soc at 3,0/SUNW,pln at a0000000,87832f/ssd at 0,0 (ssd90):
>Transport error: Fibre Channel Offline
These failures made it look like I had 6 dead disks (from the Veritas
perspective). I broke the mirrors on the volumes and was able to get
the server and file systems functional until I got the new FC/OM cards.
I replaced the fiber cable and both FC/OM (fiber channel optical modules).
1 in the array and 1 in the server. This fixed the problem. I did not have
to worry about the worldwide name because I did not replace the controller
board itself.
Thanks,
- Jeff
>----- Begin Included Message -----
>
>From jpm Wed Jan 3 10:38:35 2001
>To: codeprof at codeprof.com
>Subject: model 114 array controller upgrade
>
>Hi,
>
>I have:
>
>Ultra-2 enterprise
>Solaris 2.5.1
>Veritas 2.5.1
>model 114 array
>
>I'm going to replace the fiber plug-in cards in both
>the Ultra-2 and the 114 array. If I don't change the
>controller (scsi card) do I need to do anything with
>respect to the "worldwide name" stored on the controller?
>
>If I do change the controller, how do I "update the device
>paths to the volumes to the new worldwide name"?
>
>I'm planning on doing this later today so any quick help
>appreciated. Will summarize.
>
>Thank you,
>
>Jeff
>
>Jeffrey P. Miller
>Systems Administrator
>Eastman Kodak Company
>jeffrey.p.miller at kodak.com
>Phone: (716) 726-0208
>
>
>----- End Included Message -----